6QQD

Cryogenic temperature structure of Hen Egg White Lysozyme recorded after an accumulated dose of 10 MGy


Experimental Data Snapshot

  • Method: X-RAY DIFFRACTION
  • Resolution: 1.92 Å
  • R-Value Free: 0.216 
  • R-Value Work: 0.152 
  • R-Value Observed: 0.156 

wwPDB Validation   3D Report Full Report


This is version 1.2 of the entry. See complete history


Literature

Specific radiation damage is a lesser concern at room temperature.

Gotthard, G.Aumonier, S.De Sanctis, D.Leonard, G.von Stetten, D.Royant, A.

(2019) IUCrJ 6: 665-680

  • DOI: https://doi.org/10.1107/S205225251900616X
  • Primary Citation of Related Structures:  
    6QQ8, 6QQ9, 6QQA, 6QQB, 6QQC, 6QQD, 6QQE, 6QQF, 6QQH, 6QQI, 6QQJ, 6QQK, 6QSA

  • PubMed Abstract: 

    Carrying out macromolecular crystallography (MX) experiments at cryogenic temperatures significantly slows the rate of global radiation damage, thus facilitating the solution of high-resolution crystal structures of macromolecules. However, cryo-MX experiments suffer from the early onset of so-called specific radiation damage that affects certain amino-acid residues and, in particular, the active sites of many proteins. Here, a series of MX experiments are described which suggest that specific and global radiation damage are much less decoupled at room temperature than they are at cryogenic temperatures. The results reported here demonstrate the interest in reviving the practice of collecting MX diffraction data at room temperature and allow structural biologists to favourably envisage the development of time-resolved MX experiments at synchrotron sources.


  • Organizational Affiliation

    European Synchrotron Radiation Facility, F-38043 Grenoble, France.


Macromolecules
Find similar proteins by:  (by identity cutoff)  |  3D Structure
Entity ID: 1
MoleculeChains Sequence LengthOrganismDetailsImage
Lysozyme C129Gallus gallusMutation(s): 0 
Gene Names: LYZ
EC: 3.2.1.17
UniProt
Find proteins for P00698 (Gallus gallus)
Go to UniProtKB:  P00698
Sequence Annotations
Expand
  • Reference Sequence
Experimental Data & Validation

Experimental Data

  • Method: X-RAY DIFFRACTION
  • Resolution: 1.92 Å
  • R-Value Free: 0.216 
  • R-Value Work: 0.152 
  • R-Value Observed: 0.156 
  • Space Group: P 43 21 2
Unit Cell:
Length ( Å )Angle ( ˚ )
a = 77.96α = 90
b = 77.96β = 90
c = 37.38γ = 90
Software Package:
Software NamePurpose
REFMACrefinement
XDSdata reduction
XDSdata scaling
PHASERphasing

Structure Validation

View Full Validation Report



Entry History 

Deposition Data

Revision History  (Full details and data files)

  • Version 1.0: 2019-06-19
    Type: Initial release
  • Version 1.1: 2019-07-31
    Changes: Data collection, Database references
  • Version 1.2: 2024-10-23
    Changes: Data collection, Database references, Structure summary