☰ Navigation Tabs
Features of Reovirus Outer-Capsid Protein mu1 Revealed by Electron and Image Reconstruction of the virion at 7.0-A Resolution
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 1EJ6 experimental model PDB 1JMU experimental model PDB 1N35
Sample HUMAN REOVIRUS VIRIONS (T3D)
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument Cryogen Name ETHANE Sample Vitrification Details PLUNGED INTO ETHANE
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 7939 Reported Resolution (Å) 7 Resolution Method Other Details Refinement Type Symmetry Type POINT Point Symmetry I
Map-Model Fitting and Refinement Id 1 (1EJ6, 1JMU, 1N35) Refinement Space REAL Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type KODAK SO-163 FILM Electron Dose (electrons/Å**2) 20
Imaging Experiment 1 2 Date of Experiment 1997-12-10 2002-04-18 Temperature (Kelvin) 97 Microscope Model FEI/PHILIPS CM200FEG FEI/PHILIPS CM300FEG/T Minimum Defocus (nm) 1300 Maximum Defocus (nm) 3200 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2 Imaging Mode BRIGHT FIELD BRIGHT FIELD Specimen Holder Model Nominal Magnification 38000 39200 Calibrated Magnification 45000 47440 Source FIELD EMISSION GUN FIELD EMISSION GUN Acceleration Voltage (kV) 200 300 Imaging Details SAMPLES WERE MAINTAINED AT -176 CELSIUS DEGREE IN THE ELECTRON MICROSCOPES.
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details CTF correction of each particle