ELECTRON MICROSCOPY
| Sample |
|---|
| GATOR2 complex bound to arginine sensor CASTOR1 |
| Sample Components |
| GATOR2 Complex |
| CASTOR1 |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 140606 |
| Reported Resolution (Å) | 3.5 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | The final particle set contained 140,606 particles and a round of homogenous refinement resulted in a 3.89 A map at 0.143 FSC. |
| Refinement Type | |
| Symmetry Type | POINT |
| Point Symmetry | C1 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 | ||||
| Refinement Space | |||||
| Refinement Protocol | |||||
| Refinement Target | |||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | |||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K3 BIOQUANTUM (6k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 50 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | TFS KRIOS |
| Minimum Defocus (nm) | 1000 |
| Maximum Defocus (nm) | 2000 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | |
| Nominal Magnification | |
| Calibrated Magnification | |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| PARTICLE SELECTION | cryoSPARC | v4.3.1 |
| CTF CORRECTION | cryoSPARC | v3.3.1 |
| INITIAL EULER ASSIGNMENT | cryoSPARC | v3.3.1 |
| FINAL EULER ASSIGNMENT | cryoSPARC | v3.3.1 |
| CLASSIFICATION | cryoSPARC | v3.3.1 |
| RECONSTRUCTION | cryoSPARC | v3.3.1 |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | Patch Motion Corr. was used for motion correction and Patch CTF estimated (multi) was used for CTF determination. | 2289288 | Cryosparc blob picker with a diameter range of 200 A-280 A was used to generate 3,467,659 which was inspected to trim the particle set to 2,289,288 particles. Particles were extracted with a box size of 560x560 pixels in cryosparc2. | |