Find PDB structures and Computed Structure Models (CSM) by combining queries from tools in this suite: Attribute Search, Sequence Similarity, Sequence Motif, 3D Similarity, and 3D Motif with 'AND' logic.
Human leptin in complex with the human LEP-R ectodomain C-terminally fused to a trimeric GCN4 isoleucine zipper tag
Specimen Preparation
Sample Aggregation State
PARTICLE
Vitrification Instrument
FEI VITROBOT MARK IV
Cryogen Name
ETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
30353
Reported Resolution (Å)
6.84
Resolution Method
FSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry Type
POINT
Point Symmetry
C1
Map-Model Fitting and Refinement
Id
1 (7Z3R, 7Z3Q)
Refinement Space
REAL
Refinement Protocol
FLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Atomic models for the 2:2 and 3:3 hLeptin:hLEP-R complexes were created based on the Alphafold2 predictions for hLEP-R and hLeptin, and the crystal st ...
Atomic models for the 2:2 and 3:3 hLeptin:hLEP-R complexes were created based on the Alphafold2 predictions for hLEP-R and hLeptin, and the crystal structures for the mouse 3:3 Leptin:LEP-RIgCRH2 complex (pdb 7z3r) and the human Leptin:LEP-RCRH2 complex (pdb 7z3q)
and fitted in the cryo-EM maps via Chimera. Atomic models were further refined via real space refinement in Phenix using rigid body refinement and coordinate refinement with reference restraints to the starting model.
Data Acquisition
Detector Type
GATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)
62.4
Imaging Experiment
1
Date of Experiment
Temperature (Kelvin)
Microscope Model
JEOL CRYO ARM 300
Minimum Defocus (nm)
800
Maximum Defocus (nm)
3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging Mode
OTHER
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
EM Software
Task
Software Package
Version
PARTICLE SELECTION
cryoSPARC
v3.1.0
CTF CORRECTION
cryoSPARC
v3.1.0
MODEL FITTING
UCSF Chimera
1.17
MODEL REFINEMENT
PHENIX
1.19.2
INITIAL EULER ASSIGNMENT
cryoSPARC
v3.1.0
CLASSIFICATION
cryoSPARC
v3.1.0
CLASSIFICATION
cryoSPARC
v3.1.0
RECONSTRUCTION
cryoSPARC
v3.3.2
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
206218
Initial 2D-classes were obtained via template-based particle picking using 2D-classes for a mLeptin:mLEP-R-deltaFnIII-tGCN4 complex lowpass filtered to 20 Angstrom. These 2D classes were then used to seed template-based picking and neural network-based particle picking via Topaz 0.2.4. Junk particles were removed by multiple rounds of 2D classification resulting in a particle set of 206,218 particles. High-resolution 2D classes were selected for ab initio 3D classification followed by heterogeneous refinement and non-uniform refinement.