7QJ4

Structure of recombinant human gamma-Tubulin Ring Complex 10-spoked assembly intermediate (spokes 5-14)


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d22.397
f_angle_d1.268
f_chiral_restr0.067
f_bond_d0.019
f_plane_restr0.008
Sample
10-spoked assembly intermediate of the gamma-Tubulin Ring Complex (spokes 5-14)
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles6097
Reported Resolution (Å)9
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (7AS4, 7AS4, 7AS4, 6V6S, 6V6S, 7AS4, 7AS4, 6X0U, 6L81)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)35
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)2000
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONTopaz0.2.4
IMAGE ACQUISITIONEPU2.6
CTF CORRECTIONGctf1.06
MODEL FITTINGNAMD
MODEL FITTINGVMD
INITIAL EULER ASSIGNMENTRELION3.1
FINAL EULER ASSIGNMENTRELION3.0
CLASSIFICATIONRELION3.1
RECONSTRUCTIONRELION3.0
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION436887