7U05
Structure of the yeast TRAPPII-Rab11/Ypt32 complex in the closed/closed state (composite structure)
ELECTRON MICROSCOPY
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 5.4474 |
f_angle_d | 0.7648 |
f_chiral_restr | 0.0459 |
f_plane_restr | 0.005 |
f_bond_d | 0.0042 |
Sample |
---|
TRAPPII complex bound to Rab11/Ypt32 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | The sample was incubated on the grid for 10 seconds followed by blotting for 5 seconds before plunging in liquid ethane. |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 369488 |
Reported Resolution (Å) | 3.7 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | The composite map was generated by combining the consensus dimer map (EMD-26221) with focused refinement maps deposited in the entries EMD-26223, EMD- ... |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C2 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (3CUE, 3RWO, 3PR6) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | OTHER | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details | Model was rebuilt in coot and refined using phenix.real_space_refine. |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 BIOQUANTUM (6k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 53 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TALOS ARCTICA |
Minimum Defocus (nm) | 800 |
Maximum Defocus (nm) | 2500 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 63000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 200 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | EPU | |
CTF CORRECTION | cryoSPARC | 3.2.0 |
CTF CORRECTION | RELION | 3.1 |
MODEL FITTING | Coot | |
MODEL REFINEMENT | PHENIX | |
INITIAL EULER ASSIGNMENT | cryoSPARC | 3.2.0 |
FINAL EULER ASSIGNMENT | RELION | 3.1 |
RECONSTRUCTION | PHENIX |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | 979187 |