7TY8

Cryo-EM structure of human Anion Exchanger 1 bound to Niflumic Acid


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg29.974
r_dihedral_angle_4_deg14.594
r_dihedral_angle_3_deg14.207
r_lrange_it9.621
r_lrange_other9.621
r_mcangle_it5.018
r_mcangle_other5.018
r_dihedral_angle_1_deg4.903
r_scangle_it4.282
r_scangle_other4.281
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg29.974
r_dihedral_angle_4_deg14.594
r_dihedral_angle_3_deg14.207
r_lrange_it9.621
r_lrange_other9.621
r_mcangle_it5.018
r_mcangle_other5.018
r_dihedral_angle_1_deg4.903
r_scangle_it4.282
r_scangle_other4.281
r_mcbond_other2.86
r_mcbond_it2.859
r_scbond_it2.369
r_scbond_other2.369
r_angle_other_deg2.223
r_angle_refined_deg1.247
r_symmetry_nbd_other0.195
r_nbd_refined0.167
r_nbtor_refined0.155
r_xyhbond_nbd_refined0.115
r_symmetry_nbtor_other0.067
r_symmetry_xyhbond_nbd_other0.056
r_chiral_restr0.047
r_bond_other_d0.032
r_gen_planes_other0.009
r_gen_planes_refined0.006
r_bond_refined_d0.003
Sample
Dimeric anion exchanger 1 (SLC4A1)
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentLEICA EM GP
Cryogen NameETHANE
Sample Vitrification DetailsBlot force 3 for 3-5 seconds was used and subsequent grids were screened for ice thickness prior to data collection
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles79981
Reported Resolution (Å)3.18
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC2
Map-Model Fitting and Refinement
Id1 (4YZF)
Refinement SpaceRECIPROCAL
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)59.99
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)500
Maximum Defocus (nm)1800
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification64000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC
IMAGE ACQUISITIONLeginon
CTF CORRECTIONcryoSPARC
MODEL FITTINGUCSF ChimeraX
INITIAL EULER ASSIGNMENTcryoSPARC
FINAL EULER ASSIGNMENTcryoSPARC
CLASSIFICATIONcryoSPARC
RECONSTRUCTIONcryoSPARC
MODEL REFINEMENTREFMACservalcat
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION2977492