7RM5

MicroED structure of the human adenosine receptor at 2.8A


ELECTRON CRYSTALLOGRAPHY

Crystal Data

Unit Cell
Length ( Å )Angle ( ˚ )
a = 40.005α = 90
b = 180.54β = 90
c = 139.67γ = 90
Symmetry
Space GroupC 2 2 21

Diffraction

Diffraction Experiment
ID #Crystal IDScattering TypeData Collection TemperatureDetectorDetector TypeDetailsCollection DateMonochromatorProtocol
11 CMOS2020-09-11

Refinement

Statistics
Diffraction IDStructure Solution MethodCross Validation methodStarting modelResolution (High)Resolution (Low)Cut-off Sigma (F)Number Reflections (Observed)Number Reflections (R-Free)Percent Reflections (Observed)R-Factor (Observed)R-WorkR-FreeR-Free Selection DetailsMean Isotropic B
ELECTRON CRYSTALLOGRAPHYMOLECULAR REPLACEMENTFREE R-VALUE4EIY2.7937.911.31003552577.120.25030.24820.2881Copied from 4EIY43
Temperature Factor Modeling
Anisotropic B[1][1]Anisotropic B[1][2]Anisotropic B[1][3]Anisotropic B[2][2]Anisotropic B[2][3]Anisotropic B[3][3]

Software

Software
Software NamePurpose
DIALSdata reduction
PHASERphasing
PHENIXrefinement
Sample
Adenosine receptor A2a/Soluble cytochrome b562 chimera
Specimen Preparation
Sample Aggregation State3D ARRAY
Vitrification InstrumentLEICA EM GP
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodCRYSTALLOGRAPHY
Number of Particles
Reported Resolution (Å)2.79
Resolution MethodDIFFRACTION PATTERN/LAYERLINES
Other Details
Refinement Type
Symmetry Type3D CRYSTAL
Space Group Name
Length a40
Length b180.5
Length c180.5
Angle Alpha90
Angle Beta90
Angle Gamma90
Map-Model Fitting and Refinement
Id1 (4EIY)
Refinement SpaceRECIPROCAL
Refinement ProtocolRIGID BODY FIT
Refinement TargetMaximum likelihood
Overall B Value43
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI CETA (4k x 4k)
Electron Dose (electrons/Å**2)0.01
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeDIFFRACTION
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONEPU
MODEL FITTINGCoot
MODEL REFINEMENTPHENIX
MOLECULAR REPLACEMENTPHASER
SYMMETRY DETERMINATIONDIALS
RECONSTRUCTIONPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONE