7QHH
Desensitized state of GluA1/2 AMPA receptor in complex with TARP-gamma 8 (TMD-LBD)
ELECTRON MICROSCOPY
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
r_dihedral_angle_2_deg | 24.541 |
r_long_range_B_refined | 16.285 |
r_long_range_B_other | 16.285 |
r_dihedral_angle_3_deg | 13.195 |
r_dihedral_angle_4_deg | 7.584 |
r_mcangle_it | 5.312 |
r_mcangle_other | 5.311 |
r_dihedral_angle_1_deg | 4.863 |
r_scangle_other | 3.13 |
r_mcbond_it | 2.802 |
Sample |
---|
Complex between GluA1/2 AMPA receptor and auxiliary subunit TARP gamma8 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | 3-4 second blots |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 105918 |
Reported Resolution (Å) | 3.6 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C2 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (6QKC, 3TKD) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | RIGID BODY FIT | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details | First, rigid body fit was performed in Chimera using the coordinates of the TMD of 6QKC and the coordinates of the LBD in PDB code 3TKD. Manual model ... |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 BIOQUANTUM (6k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 51 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 340 |
Maximum Defocus (nm) | 2200 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 81000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | EPU | |
CTF CORRECTION | Gctf | |
CTF CORRECTION | RELION | 3.1 |
MODEL FITTING | Coot | |
MODEL FITTING | UCSF Chimera | |
INITIAL EULER ASSIGNMENT | RELION | 3.1 |
FINAL EULER ASSIGNMENT | RELION | 3.1 |
CLASSIFICATION | RELION | 3.1 |
RECONSTRUCTION | RELION | 3.1 |
MODEL REFINEMENT | REFMAC |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION |