EM fitted model of bacterial holo-translocon
Sample bacterial holo-translocon (HTL)
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 53648 Reported Resolution (Å) 14 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C1
Data Acquisition Detector Type FEI FALCON I (4k x 4k) Electron Dose (electrons/Å**2) 10
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI POLARA 300 Minimum Defocus (nm) Maximum Defocus (nm) Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 100 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION EMAN 2 IMAGE ACQUISITION EPU CTF CORRECTION Bsoft INITIAL EULER ASSIGNMENT SPIDER FINAL EULER ASSIGNMENT SPIDER RECONSTRUCTION RELION
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING ONLY 84732