☰ Navigation Tabs
Cryo EM density of microtubule assembled from human TUBB3
Sample Microtubule assembled from recombinant human tubulin decorated with kinesin
Specimen Preparation Sample Aggregation State HELICAL ARRAY Vitrification Instrument Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method HELICAL Number of Particles 24268 Reported Resolution (Å) 3.8 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type HELICAL Axial Symmetry C1 Axial Rise 9.44 Angular Rotation -27.69
Data Acquisition Detector Type GATAN K2 SUMMIT (4k x 4k) Electron Dose (electrons/Å**2) 27.6
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN Minimum Defocus (nm) Maximum Defocus (nm) Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model GATAN 626 SINGLE TILT LIQUID NITROGEN CRYO TRANSFER HOLDER Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version IMAGE ACQUISITION Leginon
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION