Gating movement in acetylcholine receptor analysed by time- resolved electron cryo-microscopy (open class)
ELECTRON MICROSCOPY
Starting Model(s)
| Initial Refinement Model(s) | |||
|---|---|---|---|
| Type | Source | Accession Code | Details |
| experimental model | PDB | 2BG9 | |
| Sample |
|---|
| NICOTINIC ACETYLCHOLINE RECEPTOR IN NATIVE POSTSYNAPTIC MEMBRANE FROM TORPEDO MARMORATA |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | HELICAL ARRAY |
| Vitrification Instrument | HOMEMADE PLUNGER |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | VITRIFICATION 1 -- CRYOGEN- ETHANE, HUMIDITY- 85 TEMPERATURE- 120 INSTRUMENT- HOMEMADE PLUNGER METHOD- BLOT UNTIL APPLIED DROPLET LOSES CONTACT WITH F ... |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | HELICAL |
| Number of Particles | |
| Reported Resolution (Å) | 6.2 |
| Resolution Method | |
| Other Details | FOURIER-BESSEL SYNTHESIS AFTER APPLYING DISTORTION CORRECTIONS TO THE IMAGES SUBMISSION BASED ON EXPERIMENTAL DATA FROM EMDB EMD-2072. |
| Refinement Type | |
| Symmetry Type | HELICAL |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 (2BG9) | ||||
| Refinement Space | REAL | ||||
| Refinement Protocol | FLEXIBLE FIT | ||||
| Refinement Target | |||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | METHOD--MAXIMISATION OF CORRELATION BETWEEN EXPERIMENTAL DENSITIES AND ATOMIC MODEL, USING A DEFORMABLE ELASTIC NETWORK ALGORITHM (DIREX) REFINEMENT ... | ||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | KODAK SO-163 FILM | ||||||||
| Electron Dose (electrons/Å**2) | 25 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | 2005-11-01 |
| Temperature (Kelvin) | 4 |
| Microscope Model | JEOL 3000SFF |
| Minimum Defocus (nm) | 900 |
| Maximum Defocus (nm) | 2000 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 1.6 |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | |
| Nominal Magnification | 40000 |
| Calibrated Magnification | 38500 |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details | STANDARD LOW DOSE IMAGING OF SPECIMENS OVER HOLES IN THE CARBON SUPPORT FILM |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| MODEL FITTING | DireX | |
| RECONSTRUCTION | Custom | |
| RECONSTRUCTION | MRC IMAGE PROCESSING PACKAGE | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| EACH TUBE IMAGE | ||||














