☰ Navigation Tabs
NER dual incision complex - NoF
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 8EBT
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 12.806 f_angle_d 0.428 f_chiral_restr 0.037 f_plane_restr 0.003 f_bond_d 0.002
Sample NER dual incision complex without XPF
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 64352 Reported Resolution (Å) 5.7 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C1
Map-Model Fitting and Refinement Id 1 (8ebt) Refinement Space REAL Refinement Protocol AB INITIO MODEL Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 50
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS KRIOS Minimum Defocus (nm) 800 Maximum Defocus (nm) 2400 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification 81000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION Gautomatch IMAGE ACQUISITION SerialEM CTF CORRECTION Gctf MODEL FITTING UCSF Chimera MODEL REFINEMENT PHENIX 1.21rc1_5127 INITIAL EULER ASSIGNMENT RELION 4.0 FINAL EULER ASSIGNMENT RELION 4.0 RECONSTRUCTION RELION 4.0
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION