☰ Navigation Tabs
One Lmod2 at the pointed end of F-actin
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 8F8S
Sample One Lmod2 at the pointed end of F-actin Sample Components F-actin
Specimen Preparation Sample Aggregation State FILAMENT Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 55396 Reported Resolution (Å) 3.28 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Number of Particles 55396 Reported Resolution (Å) 3.28 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Number of Particles 55396 Reported Resolution (Å) 3.28 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Number of Particles 55396 Reported Resolution (Å) 3.28 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Number of Particles 55396 Reported Resolution (Å) 3.28 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Number of Particles 55396 Reported Resolution (Å) 3.28 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Number of Particles 55396 Reported Resolution (Å) 3.28 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Number of Particles 55396 Reported Resolution (Å) 3.28 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT
Map-Model Fitting and Refinement Id 1 (8F8S) Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) GATAN K3 (6k x 4k) GATAN K3 (6k x 4k) GATAN K3 (6k x 4k) GATAN K3 (6k x 4k) GATAN K3 (6k x 4k) GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 49 49 49 49 49 49 49
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS KRIOS Minimum Defocus (nm) 500 Maximum Defocus (nm) 2500 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification 81000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION cryoSPARC IMAGE ACQUISITION EPU MODEL FITTING Coot MODEL REFINEMENT PHENIX RECONSTRUCTION PHENIX
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details NONE NONE