9Z7V | pdb_00009z7v

Cryo-EM Structure of the Type III-Bv CRISPR Complex from Dissulfurispira thermophila bound to target RNA with complementary PFS


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
in silico modelAlphaFold 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d14.401
f_angle_d0.649
f_chiral_restr0.045
f_plane_restr0.006
f_bond_d0.003
Sample
Type III-Bv CRISPR complex from Dissulfurispira thermophila bound to target RNA with a complementary PFS
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles157742
Reported Resolution (Å)3
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsNon-Uniform refinement with per particle CTF correction was used to generate the final reconstruction.
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement TargetCross-correlation coefficient
Overall B Value
Fitting Procedure
DetailsChimeraX's fit in map command was used to fit Alphafold predicted structure of individual subunits followed by refinement in PHENIX and manual editing ...ChimeraX's fit in map command was used to fit Alphafold predicted structure of individual subunits followed by refinement in PHENIX and manual editing in COOT.
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)65
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TALOS ARCTICA
Minimum Defocus (nm)500
Maximum Defocus (nm)2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification45000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC4.7.1
IMAGE ACQUISITIONSerialEM4.2.0
CTF CORRECTIONcryoSPARC4.7.1
MODEL FITTINGUCSF ChimeraX1.10.1
INITIAL EULER ASSIGNMENTcryoSPARC4.7.1
FINAL EULER ASSIGNMENTcryoSPARC4.7.1
CLASSIFICATIONcryoSPARC4.7.1
RECONSTRUCTIONcryoSPARC4.7.1
MODEL REFINEMENTPHENIX1.21.2_5419
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION3264182Particles picked using a de novo template generated in CryoSPARC live that contained 329559 particles.