9SWO | pdb_00009swo

The catalytic core of yeast telomerase holoenzyme


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_lrange_it43.496
r_lrange_other43.496
r_mcangle_it20.493
r_mcangle_other20.491
r_scangle_it19.671
r_scangle_other19.67
r_dihedral_angle_6_deg14.064
r_dihedral_angle_1_deg12.244
r_dihedral_angle_3_deg11.983
r_mcbond_it11.777
RMS Deviations
KeyRefinement Restraint Deviation
r_lrange_it43.496
r_lrange_other43.496
r_mcangle_it20.493
r_mcangle_other20.491
r_scangle_it19.671
r_scangle_other19.67
r_dihedral_angle_6_deg14.064
r_dihedral_angle_1_deg12.244
r_dihedral_angle_3_deg11.983
r_mcbond_it11.777
r_mcbond_other11.777
r_scbond_it11.23
r_scbond_other11.229
r_paralell_plane_angle_deg8.923
r_dihedral_angle_2_deg4.441
r_dihedral_angle_other_2_deg3.212
r_angle_refined_deg1.149
r_angle_other_deg0.578
r_nbd_refined0.199
r_nbtor_refined0.183
r_symmetry_nbd_other0.168
r_xyhbond_nbd_refined0.153
r_bond_refined_d0.086
r_chiral_restr0.08
r_symmetry_nbtor_other0.064
r_ext_dist_refined_b0.017
r_gen_planes_refined0.005
r_symmetry_xyhbond_nbd_other0.005
r_gen_planes_other0.003
r_bond_other_d
Sample
The catalytic core of yeast telomerase holoenzyme
Sample Components
Yeast telomerase catalytic core
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification DetailsBlot Force: 10 Blot Time: 7.0 s Wait Time: 5 min
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles125104
Reported Resolution (Å)3.7
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON IV (4k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)2400
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification130000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION5
MODEL REFINEMENTREFMAC5.8.0430
CTF CORRECTIONCTFFIND
INITIAL EULER ASSIGNMENTcryoSPARC4.5
FINAL EULER ASSIGNMENTcryoSPARC4.5
CLASSIFICATIONcryoSPARC4.5
RECONSTRUCTIONcryoSPARC4.5
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION1876851