Skip to main content

 9SVH | pdb_00009svh

Cryo-EM structure of CRBN bound to 1-[1-(4-piperidyl)indol-4-yl]hexahydropyrimidine-2,4-dione in the closed conformation


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 9SUN 
experimental modelPDB 8D81 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d4.535
f_angle_d0.6277
f_chiral_restr0.045
f_plane_restr0.0074
f_bond_d0.0037
Sample
Complex of CRL4 E3 adapter-receptor pair DDB1 and CRBN bound to 1-[1-(4-piperidyl)indol-4-yl]hexahydropyrimidine-2,4-dione
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles56510
Reported Resolution (Å)3.66
Resolution MethodFSC 0.143 CUT-OFF
Other DetailscryoSPARC non-uniform refinement was used for the final reconstruction of the consensus map, and cryoSPARC local refinement was used for the locally r ...cryoSPARC non-uniform refinement was used for the final reconstruction of the consensus map, and cryoSPARC local refinement was used for the locally refined map of the LON and thalidomide binding domains
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (9SUN, 8D81)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
DetailsInitial fitting was done in ChimeraX, followed by flexible fitting in Coot. The model was refined with iterative rounds of building in Coot and refine ...Initial fitting was done in ChimeraX, followed by flexible fitting in Coot. The model was refined with iterative rounds of building in Coot and refinement in PHENIX real space refine
Data Acquisition
Detector TypeTFS FALCON 4i (4k x 4k)
Electron Dose (electrons/Å**2)21.94
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS GLACIOS
Minimum Defocus (nm)1700
Maximum Defocus (nm)3200
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification190000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC4.6.2
CTF CORRECTIONcryoSPARC4.6.2
MODEL FITTINGUCSF ChimeraX1.9
MODEL FITTINGCoot0.9.8.95
INITIAL EULER ASSIGNMENTcryoSPARC4.6.2
FINAL EULER ASSIGNMENTcryoSPARC4.7
RECONSTRUCTIONcryoSPARC4.7
MODEL REFINEMENTPHENIX1.20.1-4487
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTIONPatch CTF