9SKZ | pdb_00009skz

Cryo-EM structure of H. neapolitanus CsoSCA C283A/C284A inactive mutant, dimer, state 2


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
in silico modelAlphaFoldAF-O85042-F1 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
s_dihedral_angle_6_deg14.4622
s_dihedral_angle_3_deg12.8683
s_dihedral_angle_1_deg6.7495
s_dihedral_angle_2_deg4.435
s_angle_nonh_deg2.0468
s_nbtor0.2385
s_nbd0.2247
s_hbond_nbd0.2045
s_metal_ion0.154
s_chiral_restr0.0938
RMS Deviations
KeyRefinement Restraint Deviation
s_dihedral_angle_6_deg14.4622
s_dihedral_angle_3_deg12.8683
s_dihedral_angle_1_deg6.7495
s_dihedral_angle_2_deg4.435
s_angle_nonh_deg2.0468
s_nbtor0.2385
s_nbd0.2247
s_hbond_nbd0.2045
s_metal_ion0.154
s_chiral_restr0.0938
s_bond_nonh_d0.0114
s_planes0.0092
Sample
HnCsoSCA_C283A-C284A
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details4C, 100% relative humidity, delay time 0s, blot time 3s, blot force 0
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles525107
Reported Resolution (Å)2.22
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsThe final reconstruction was produced by classifying dimers, regrouping similar 3D classes, and running local refinement with signal-subtracted partic ...The final reconstruction was produced by classifying dimers, regrouping similar 3D classes, and running local refinement with signal-subtracted particle images.
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement SpaceRECIPROCAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)68.973
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)600
Maximum Defocus (nm)1800
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification130000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONTopaz0.2.5
IMAGE ACQUISITIONEPU3.6.0
CTF CORRECTIONcryoSPARC4.7
MODEL FITTINGUCSF ChimeraX1.9
MODEL FITTINGISOLDE1.9
MODEL REFINEMENTServalcat0.4.99
INITIAL EULER ASSIGNMENTcryoSPARC4.7
FINAL EULER ASSIGNMENTcryoSPARC4.7
CLASSIFICATIONcryoSPARC4.7
RECONSTRUCTIONcryoSPARC4.7
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION497507Particles were picked with topaz, trained with a set of about 1000 particles picked manually from micrographs denoised by CryoSPARC. Topaz was trained and applied on raw micrographs.