Serial electron diffraction (SerialED) structure of Ribonucleotide reductase R2 from E. coli in its reduced (red) form


ELECTRON CRYSTALLOGRAPHY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 9SK1 

Crystal Data

Unit Cell
Length ( Å )Angle ( ˚ )
a = 73.95α = 90
b = 76.54β = 90
c = 145.74γ = 90
Symmetry
Space GroupP 21 21 21

Data Collection

Refinement

Statistics
Diffraction IDStructure Solution MethodCross Validation methodResolution (High)Resolution (Low)Cut-off Sigma (F)Number Reflections (Observed)Number Reflections (R-Free)Percent Reflections (Observed)R-Factor (Observed)R-Work (Depositor)R-Work (DCC)R-Free (Depositor)R-Free (DCC)Mean Isotropic B
ELECTRON CRYSTALLOGRAPHYFREE R-VALUE1.819.931.3367204157486.960.20080.19970.21750.24680.246624.7
Temperature Factor Modeling
Anisotropic B[1][1]Anisotropic B[1][2]Anisotropic B[1][3]Anisotropic B[2][2]Anisotropic B[2][3]Anisotropic B[3][3]
RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d5.9732
f_angle_d0.816
f_chiral_restr0.0488
f_plane_restr0.0228
f_bond_d0.0089
Sample
Ribonucleotide reductase R2 from E. coli in its reduced (red) form
Specimen Preparation
Sample Aggregation State3D ARRAY
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification DetailsExcess liquid was manually blotted from the backside for approximately 10 seconds, followed by plunge freezing in liquid ethane. Sample was prepared i ...Excess liquid was manually blotted from the backside for approximately 10 seconds, followed by plunge freezing in liquid ethane. Sample was prepared in an inert environment within a glove box.
3D Reconstruction
Reconstruction MethodCRYSTALLOGRAPHY
Number of Particles
Reported Resolution (Å)1.8
Resolution MethodDIFFRACTION PATTERN/LAYERLINES
Other Details
Refinement Type
Symmetry Type3D CRYSTAL
Space Group Name
Length a73.95
Length b76.54
Length c76.54
Angle Alpha90
Angle Beta90
Angle Gamma90
Map-Model Fitting and Refinement
Id1 (9SK1)
Refinement SpaceRECIPROCAL
Refinement ProtocolOTHER
Refinement TargetMaximum-likelihood
Overall B Value24.7
Fitting Procedure
Details
Data Acquisition
Detector TypeOTHER
Electron Dose (electrons/Å**2)1.38
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)1
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeDIFFRACTION
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging DetailsTo address the preferred orientation of ribbon-shaped crystals on the grid, SerialED data was collected at tilt angles of 0, 10, 25, 45, and 60 degrees. Lower tilts minimized absorption for improved resolution, while higher tilts expanded reciprocal space coverage.
EM Software
TaskSoftware PackageVersion
MODEL FITTINGPHENIX1.20.1-4487
MOLECULAR REPLACEMENTPHENIX
RECONSTRUCTIONPHENIX
MODEL REFINEMENTPHENIX1.20.1-4487
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONE