9RMK | pdb_00009rmk

Structure of the O-oligosaccharyl transferase PglL from Neisseria meningitidis in complex with a nanobody


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined25.167
r_long_range_B_other25.166
r_scangle_other18.501
r_dihedral_angle_2_deg17.554
r_dihedral_angle_3_deg15.271
r_mcangle_it13.989
r_mcangle_other13.988
r_scbond_it11.057
r_scbond_other11.056
r_mcbond_it8.594
RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined25.167
r_long_range_B_other25.166
r_scangle_other18.501
r_dihedral_angle_2_deg17.554
r_dihedral_angle_3_deg15.271
r_mcangle_it13.989
r_mcangle_other13.988
r_scbond_it11.057
r_scbond_other11.056
r_mcbond_it8.594
r_mcbond_other8.589
r_dihedral_angle_1_deg4.276
r_angle_refined_deg1.326
r_angle_other_deg0.445
r_chiral_restr0.059
r_bond_refined_d0.007
r_gen_planes_refined0.005
r_gen_planes_other0.001
r_bond_other_d
r_dihedral_angle_4_deg
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
PglL in complex with a nanobody
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles59547
Reported Resolution (Å)3.3
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)65
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification130000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC3.2
MODEL REFINEMENTREFMAC5.8.0430
CTF CORRECTIONCTFFIND4
RECONSTRUCTIONcryoSPARC3.2
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION