Structure of human MTH1 in complex with 8DG by continuous serial electron diffraction (SerialED)


ELECTRON CRYSTALLOGRAPHY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 3ZR1 

Crystal Data

Unit Cell
Length ( Å )Angle ( ˚ )
a = 59.34α = 90
b = 67.55β = 90
c = 80.11γ = 90
Symmetry
Space GroupP 21 21 21

Data Collection

Refinement

Statistics
Diffraction IDStructure Solution MethodCross Validation methodResolution (High)Resolution (Low)Cut-off Sigma (F)Number Reflections (Observed)Number Reflections (R-Free)Percent Reflections (Observed)R-Factor (Observed)R-Work (Depositor)R-Work (DCC)R-Free (Depositor)R-Free (DCC)R-Free Selection DetailsMean Isotropic B
ELECTRON CRYSTALLOGRAPHYFREE R-VALUE1.6625.731.3337120185696.390.20740.20510.23130.25280.2757Random selection30.4
Temperature Factor Modeling
Anisotropic B[1][1]Anisotropic B[1][2]Anisotropic B[1][3]Anisotropic B[2][2]Anisotropic B[2][3]Anisotropic B[3][3]
RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d16.7298
f_angle_d0.9472
f_chiral_restr0.059
f_bond_d0.0104
f_plane_restr0.0079
Sample
7,8-dihydro-8-oxoguanine triphosphatase
Specimen Preparation
Sample Aggregation State3D ARRAY
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification DetailsManual blotting at room temperature with ambient humidity
3D Reconstruction
Reconstruction MethodCRYSTALLOGRAPHY
Number of Particles
Reported Resolution (Å)1.66
Resolution MethodDIFFRACTION PATTERN/LAYERLINES
Other Details
Refinement Type
Symmetry Type3D CRYSTAL
Space Group Name
Length a59.34
Length b67.55
Length c67.55
Angle Alpha90
Angle Beta90
Angle Gamma90
Map-Model Fitting and Refinement
Id1 (3ZR1)
Refinement SpaceRECIPROCAL
Refinement ProtocolOTHER
Refinement Targetmaximum-likelihood
Overall B Value30.11
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI CETA (4k x 4k)
Electron Dose (electrons/Å**2)5.63
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeDIFFRACTION
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
RECONSTRUCTIONPHENIX
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONE