9QAX | pdb_00009qax

The catalytic core with C2 symmetry of human telomerase dimer


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 7QXA 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined66.448
r_long_range_B_other66.447
r_scangle_other35.533
r_mcangle_it34.941
r_mcangle_other34.939
r_mcbond_it21.283
r_mcbond_other21.281
r_scbond_it21.026
r_scbond_other21.025
r_dihedral_angle_3_deg12.086
RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined66.448
r_long_range_B_other66.447
r_scangle_other35.533
r_mcangle_it34.941
r_mcangle_other34.939
r_mcbond_it21.283
r_mcbond_other21.281
r_scbond_it21.026
r_scbond_other21.025
r_dihedral_angle_3_deg12.086
r_dihedral_angle_1_deg6.016
r_dihedral_angle_2_deg3.447
r_angle_refined_deg1.323
r_angle_other_deg0.627
r_chiral_restr0.062
r_gen_planes_refined0.007
r_bond_refined_d0.006
r_gen_planes_other0.003
r_bond_other_d0.001
r_dihedral_angle_4_deg
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
The catalytic core with C2 symmetry of human telomerase dimer
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles272757
Reported Resolution (Å)3.3
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (7QXA)
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)48
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)2400
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification81000
Calibrated Magnification45872
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION4.0
IMAGE ACQUISITIONEPU2.13.0.3175REL
CTF CORRECTIONCTFFIND4
MODEL FITTINGCoot0.9.8.1
MODEL FITTINGUCSF ChimeraX1.5
INITIAL EULER ASSIGNMENTRELION4.0
FINAL EULER ASSIGNMENTRELION5.0
CLASSIFICATIONRELION5.0
RECONSTRUCTIONRELION5.0
MODEL REFINEMENTREFMAC5.8
MODEL REFINEMENTServalcat0.4.70
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION1871285