CryoEM structure of the CCDC6-PP2Ac multimer
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 5.228 f_angle_d 1.054 f_chiral_restr 0.056 f_plane_restr 0.008 f_bond_d 0.006
Sample Complex of FBXO42-CCDC6-PP2Ac
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 215302 Reported Resolution (Å) 3.5 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT
Map-Model Fitting and Refinement Id 1 Refinement Space REAL Refinement Protocol FLEXIBLE FIT Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 BIOQUANTUM (6k x 4k) Electron Dose (electrons/Å**2) 45
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS KRIOS Minimum Defocus (nm) 800 Maximum Defocus (nm) 2400 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification 105000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION cryoSPARC IMAGE ACQUISITION SerialEM CTF CORRECTION cryoSPARC MODEL REFINEMENT PHENIX 1.20.1_4487 INITIAL EULER ASSIGNMENT cryoSPARC FINAL EULER ASSIGNMENT cryoSPARC CLASSIFICATION cryoSPARC RECONSTRUCTION cryoSPARC