| NMR Experiment |
|---|
| Experiment | Type | Sample Contents | Solvent | Ionic Strength | pH | Pressure | Temperature (K) | Spectrometer |
|---|
| 1 | 1D 1H | 2.78 mM uniform 15N LR4-814 | 93% H2O/7% D2O | 0 | 5 | 1 atm | 297 | Bruker AVANCE NEO 700 |
| 2 | 2D TOCSY (mix = 15 ms) | 2.78 mM uniform 15N LR4-814 | 93% H2O/7% D2O | 0 | 5 | 1 atm | 297 | Bruker AVANCE NEO 700 |
| 3 | 2D TOCSY (mix = 60 ms) | 2.78 mM uniform 15N LR4-814 | 93% H2O/7% D2O | 0 | 5 | 1 atm | 297 | Bruker AVANCE NEO 700 |
| 4 | 2D NOESY (mix = 200 ms) | 2.78 mM uniform 15N LR4-814 | 93% H2O/7% D2O | 0 | 5 | 1 atm | 297 | Bruker AVANCE NEO 700 |
| 5 | 2D 1H-15N sofastHMQC | 2.78 mM uniform 15N LR4-814 | 93% H2O/7% D2O | 0 | 5 | 1 atm | 297 | Bruker AVANCE NEO 700 |
| 6 | 3D 1H-1H-15N-NOESY-HSQC (mix = 200 ms) | 2.78 mM uniform 15N LR4-814 | 93% H2O/7% D2O | 0 | 5 | 1 atm | 297 | Bruker AVANCE NEO 700 |
| 7 | 2D 1H-13C HSQC | 2.78 mM uniform 15N LR4-814 | 93% H2O/7% D2O | 0 | 5 | 1 atm | 297 | Bruker AVANCE NEO 700 |