☰ Navigation Tabs
Cryo-EM structure of GPR3-1IU9 complex
Sample dimer state of GPR3 with PGS
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 205789 Reported Resolution (Å) 3.66 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C1
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol RIGID BODY FIT Refinement Target Overall B Value 118.6 Fitting Procedure Details
Data Acquisition Detector Type FEI FALCON IV (4k x 4k) Electron Dose (electrons/Å**2) 60
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TECNAI ARCTICA Minimum Defocus (nm) 1000 Maximum Defocus (nm) 2000 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION