9I3P | pdb_00009i3p

CryoEM structure of the Themis:Grb2 complex with bound ProMacrobody 256


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
in silico modelAlphaFold 
in silico modelOther 
experimental modelPDB 7OMT 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d4.717
f_angle_d0.528
f_chiral_restr0.042
f_plane_restr0.004
f_bond_d0.002
Sample
Themis-Grb2 complex bound to ProMacrobody 256
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentLEICA EM GP
Cryogen NameETHANE
Sample Vitrification DetailsLeica EM GP2, 5 s blotting time
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles601216
Reported Resolution (Å)3.3
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (7OMT)
Refinement Space
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)61.8
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelJEOL CRYO ARM 300
Minimum Defocus (nm)1400
Maximum Defocus (nm)1900
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification60000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARCv4.5.1
PARTICLE SELECTIONcrYOLO
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONcryoSPARCv4.5.1
MODEL FITTINGUCSF ChimeraX1.8
MODEL FITTINGNAMD
INITIAL EULER ASSIGNMENTcryoSPARCv4.5.1
FINAL EULER ASSIGNMENTcryoSPARCv4.5.1
CLASSIFICATIONcryoSPARCv4.5.1
RECONSTRUCTIONcryoSPARC
MODEL REFINEMENTPHENIX1.21.1_5286:
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION