9HB4 | pdb_00009hb4

Hexameric RuvBL1/RuvBL2 bound to SPAG1 C-ter


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d7.932
f_angle_d0.708
f_chiral_restr0.044
f_plane_restr0.004
f_bond_d0.003
Sample
Hexameric RuvBL1/RuvBL2 complex bound to C-terminal Reagion of SPAG1
Sample Components
Components that form the hexameric Ring
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentLEICA EM GP
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles167033
Reported Resolution (Å)3.56
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement TargetCross-correlation coefficient
Overall B Value126
Fitting Procedure
DetailsInitial Local fitting was done using chimera, and PHENIX was used for flexible fitting
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)51.92
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)900
Maximum Defocus (nm)2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification130000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.0
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONGctf
MODEL FITTINGUCSF Chimera1.17
MODEL REFINEMENTPHENIX1.21
INITIAL EULER ASSIGNMENTRELION3.0
FINAL EULER ASSIGNMENTRELION3.0
CLASSIFICATIONRELION3.0
RECONSTRUCTIONRELION3.0
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION2158039