9BDR | pdb_00009bdr

Cryo-EM structure of cardiac amyloid fibril from a variant ATTRV122delta, double filament morphology 1


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 9BDM 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d4.962
f_angle_d0.568
f_chiral_restr0.051
f_plane_restr0.005
f_bond_d0.003
Sample
Transthyretin fibrils
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles40635
Reported Resolution (Å)3.82
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise4.88
Angular Rotation-1.15
Map-Model Fitting and Refinement
Id1 (9BDM)
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value97
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON IV (4k x 4k)
Electron Dose (electrons/Å**2)40
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)900
Maximum Defocus (nm)2200
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION4.0
IMAGE ACQUISITIONEPU3.5
CTF CORRECTIONCTFFIND4.1
MODEL FITTINGCoot0.9.8.1
INITIAL EULER ASSIGNMENTRELION4.0
FINAL EULER ASSIGNMENTRELION4.0
CLASSIFICATIONRELION4.0
RECONSTRUCTIONRELION4.0
MODEL REFINEMENTPHENIX1.20.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONE726223