9B73 | pdb_00009b73

Cryo-EM structure of the desensitised ATP-bound human P2X1 receptor


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
in silico modelAlphaFoldP51575 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d12.0651
f_angle_d0.4747
f_chiral_restr0.045
f_plane_restr0.0056
f_bond_d0.0031
Sample
P2X1 receptor trimer
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK III
Cryogen NameETHANE
Sample Vitrification DetailsGrids were frozen in liquid ethane using a Vitrobot Mark III operated at 4 degrees Celsius and 100% humidity with 12 blot force and 2 seconds blot tim ...Grids were frozen in liquid ethane using a Vitrobot Mark III operated at 4 degrees Celsius and 100% humidity with 12 blot force and 2 seconds blot time.
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles481309
Reported Resolution (Å)1.96
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC3
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value60.7
Fitting Procedure
DetailsInitial fitting was performed in Chimerax and then refinements were performed in Coot and Phenix.
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)60
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)500
Maximum Defocus (nm)1500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification105000
Calibrated Magnification105000
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging DetailsInitial grid screening was conducted using a 200kV TFS Artica cryo-electron microscope prior to imaging on a Titan Krios cryo-electron microscope.
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC1.3
CTF CORRECTIONcryoSPARC1.3
MODEL FITTINGCoot0.9.8.92
MODEL REFINEMENTPHENIX1.20.1
INITIAL EULER ASSIGNMENTcryoSPARC1.3
FINAL EULER ASSIGNMENTcryoSPARC1.3
CLASSIFICATIONcryoSPARC1.3
RECONSTRUCTIONcryoSPARC1.3
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTIONCTF correction was performed on the initial set of motion-corrected images, followed by subsequent local CTF corrections on the final subset of particles.5312810Initially, 2,565,511 particles were picked for the higher concentration fluor-FC8 P2X1 receptor sample, and 2,747,299 particles were picked for the lower concentration sample.