☰ Navigation Tabs
Cryo-EM structure and molecular assembly of the BoNT-like toxin PG1 complex from Paeniclostridium ghonii
Refinement RMS Deviations Key Refinement Restraint Deviation r_dihedral_angle_2_deg 37.255 r_dihedral_angle_3_deg 19.89 r_dihedral_angle_4_deg 19.238 r_dihedral_angle_1_deg 5.3 r_angle_other_deg 2.207 r_angle_refined_deg 1.241 r_symmetry_nbd_other 0.247 r_xyhbond_nbd_refined 0.219 r_nbd_refined 0.192 r_nbtor_refined 0.18
Show All KeysRMS Deviations Key Refinement Restraint Deviation r_dihedral_angle_2_deg 37.255 r_dihedral_angle_3_deg 19.89 r_dihedral_angle_4_deg 19.238 r_dihedral_angle_1_deg 5.3 r_angle_other_deg 2.207 r_angle_refined_deg 1.241 r_symmetry_nbd_other 0.247 r_xyhbond_nbd_refined 0.219 r_nbd_refined 0.192 r_nbtor_refined 0.18 r_symmetry_xyhbond_nbd_other 0.115 r_symmetry_nbtor_other 0.074 r_chiral_restr 0.061 r_bond_other_d 0.035 r_bond_refined_d 0.01 r_gen_planes_other 0.007 r_gen_planes_refined 0.005 r_mcbond_it r_mcbond_other r_mcangle_it r_mcangle_other r_scbond_it r_scbond_other r_scangle_it r_scangle_other r_lrange_it r_lrange_other
Hide All Keys
Sample Cryo-EM structure and molecular assembly of the BoNT-like toxin PG1 complex from Paeniclostridium ghonii
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 364136 Reported Resolution (Å) 3.2 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol AB INITIO MODEL Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type FEI FALCON III (4k x 4k) Electron Dose (electrons/Å**2) 53.19
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 1000 Maximum Defocus (nm) 2200 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION cryoSPARC 4.4.1 CTF CORRECTION cryoSPARC 4.4.1 MODEL REFINEMENT PHENIX 1.19.2 INITIAL EULER ASSIGNMENT cryoSPARC 4.4.1 FINAL EULER ASSIGNMENT cryoSPARC 4.4.1 CLASSIFICATION cryoSPARC 4.4.1 RECONSTRUCTION cryoSPARC 4.4.1
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details NONE