8WIC

Cryo- EM structure of Mycobacterium smegmatis 50S ribosomal subunit (body 1) of 70S ribosome, E- tRNA and RafH.


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d15.619
f_angle_d0.65
f_chiral_restr0.038
f_bond_d0.006
f_plane_restr0.006
Sample
70S ribosome + RafH protein
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles44299
Reported Resolution (Å)3.5
Resolution MethodOTHER
Other DetailsAd-hoc low pass filter 3.5 Angstrom
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (8WHX)
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value
Fitting Procedure
Detailsphenix.real_space_refinement
Data Acquisition
Detector TypeFEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)1.34
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1800
Maximum Defocus (nm)3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.1.4
IMAGE ACQUISITIONEPU
CTF CORRECTIONCTFFINDctffind/4.1.14
MODEL FITTINGCootv.0.9.3
MODEL REFINEMENTPHENIX
INITIAL EULER ASSIGNMENTRELION3.1.4
FINAL EULER ASSIGNMENTRELION3.1.4
CLASSIFICATIONRELION3.1.4
RECONSTRUCTIONRELION3.1.4
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONECTF correction in Relion