Cryo-EM structure of the ABC transporter PCAT1 bound with Mg_class_2
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 3.9147 f_angle_d 0.5026 f_chiral_restr 0.0398 f_plane_restr 0.0031 f_bond_d 0.0025
Specimen Preparation Sample Aggregation State PARTICLE
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 556419 Reported Resolution (Å) 2.97 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 1.14708
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS KRIOS Minimum Defocus (nm) 800 Maximum Defocus (nm) 2000 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION cryoSPARC 4.2.1 CTF CORRECTION cryoSPARC 4.2.1 CLASSIFICATION cryoSPARC 4.2.1 RECONSTRUCTION cryoSPARC 4.2.1 MODEL REFINEMENT PHENIX 1.20.1-4487
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details NONE 3432341