☰ Navigation Tabs
Diversity-generating retroelement (DGR) ribonucleoprotein reverse transcriptase - Pre-active State 2
Refinement RMS Deviations Key Refinement Restraint Deviation r_long_range_B_refined 47.227 r_long_range_B_other 47.226 r_mcangle_it 30.098 r_mcangle_other 30.094 r_scangle_other 29.506 r_dihedral_angle_3_deg 25.11 r_mcbond_it 21.313 r_mcbond_other 21.313 r_scbond_it 19.631 r_scbond_other 19.63
Show All KeysRMS Deviations Key Refinement Restraint Deviation r_long_range_B_refined 47.227 r_long_range_B_other 47.226 r_mcangle_it 30.098 r_mcangle_other 30.094 r_scangle_other 29.506 r_dihedral_angle_3_deg 25.11 r_mcbond_it 21.313 r_mcbond_other 21.313 r_scbond_it 19.631 r_scbond_other 19.63 r_dihedral_angle_1_deg 7.277 r_dihedral_angle_2_deg 5.815 r_angle_refined_deg 1.991 r_angle_other_deg 0.579 r_chiral_restr 0.122 r_bond_refined_d 0.011 r_gen_planes_refined 0.008 r_gen_planes_other 0.002 r_bond_other_d r_dihedral_angle_4_deg r_nbd_refined r_nbd_other r_nbtor_refined r_nbtor_other r_xyhbond_nbd_refined r_xyhbond_nbd_other r_metal_ion_refined r_metal_ion_other r_symmetry_vdw_refined r_symmetry_vdw_other r_symmetry_hbond_refined r_symmetry_hbond_other r_symmetry_metal_ion_refined r_symmetry_metal_ion_other r_scangle_it r_rigid_bond_restr r_sphericity_free r_sphericity_bonded
Hide All Keys
Sample Diversity-generating retroelement (DGR) ribonucleoprotein reverse transcriptase without dNTP
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 202034 Reported Resolution (Å) 3.05 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 55
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 400 Maximum Defocus (nm) 2000 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version IMAGE ACQUISITION SerialEM MODEL FITTING Coot CLASSIFICATION cryoSPARC RECONSTRUCTION cryoSPARC 3.1.1 MODEL REFINEMENT CCP4 package
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING ONLY