8U18

Cryo-EM structure of murine Thrombopoietin receptor ectodomain in complex with Tpo


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d9.94
f_angle_d0.728
f_chiral_restr0.044
f_plane_restr0.006
f_bond_d0.004
Sample
2:1 complex of the mouse thrombopoietin receptor ectodomain and mouse thrombopoietin
Sample Components
mouse thrombopoietin receptor ectodomain
mouse thrombopoietin
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification DetailsBlot time of 4 s, blot force of 6 and no wait time or drain time.
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles745000
Reported Resolution (Å)3.6
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsFinal map was generated using Non-uniform refinement followed by 3DFlex refinement in cryoSPARC. Map was sharpened by deepEMhancer.
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement TargetCross-correlation coefficient
Overall B Value
Fitting Procedure
DetailsChimeraX was used to perform rigid-body fitting of domains and modelling was performed using Coot and ISOLDE. Refinement was carried out in PHENIX.
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)50.57
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)400
Maximum Defocus (nm)3600
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification130000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC4.2.1
IMAGE ACQUISITIONEPU2
CTF CORRECTIONcryoSPARC4.2.1
MODEL FITTINGISOLDE1.6.0
MODEL FITTINGUCSF ChimeraX1.6.1
MODEL FITTINGCoot0.9.8.3
INITIAL EULER ASSIGNMENTcryoSPARC4.2.1
FINAL EULER ASSIGNMENTcryoSPARC4.2.1
CLASSIFICATIONcryoSPARC4.2.1
RECONSTRUCTIONcryoSPARC4.2.1
MODEL REFINEMENTPHENIX1.20.1_4487
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONEDefocus values were estimated using patch CTF estimation and CTF correction was performed during 3D reccnstruction.2353523Templates for picking were generated using a gaussian based picking approach, followed by 2D classification and selection of high-quality 2D classes for template picking.