8RI9

Late alpha-Synuclein fibril structure from liquid-liquid phase separations.


ELECTRON MICROSCOPY
Sample
Fibrillar complex of alpha-synuclein
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles40855
Reported Resolution (Å)3.3
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise4.73
Angular Rotation-1.23
Map-Model Fitting and Refinement
Id1 (6H6B)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)43
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)900
Maximum Defocus (nm)3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification120000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.1
IMAGE ACQUISITIONEPU
CTF CORRECTIONCTFFIND
INITIAL EULER ASSIGNMENTRELION3.1
FINAL EULER ASSIGNMENTRELION
CLASSIFICATIONRELION3.1
RECONSTRUCTIONRELION3.1.3
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION465053Fibrils manually picked end-to-end prior to extraction of segments