8QYX | pdb_00008qyx

Human 60S ribosomal subunit


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 6EKO 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d14.556
f_angle_d0.571
f_chiral_restr0.036
f_plane_restr0.005
f_bond_d0.004
Sample
Human mature large ribosomal subunit
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles880876
Reported Resolution (Å)1.78
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (6EKO)
Refinement SpaceREAL
Refinement ProtocolOTHER
Refinement TargetCross-correlation coefficient
Overall B Value
Fitting Procedure
DetailsInteractive model building was performed in Coot using an auto sharpened map in cryoSPARC and additionally a low-pass-filtered map to 4 Angstrom for ...Interactive model building was performed in Coot using an auto sharpened map in cryoSPARC and additionally a low-pass-filtered map to 4 Angstrom for the more mobile regions of the 60S structure. Each residue of the model was checked individually for modifications and adjusted manually with a subsequent refinement in phenix.refine. Polyamines and metals were added while searching for unmodelled blobs in Coot. Water molecules were added using phenix.douse and visually validated in Coot. The model was validated using Molprobity.
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)49
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)500
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification105000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC3.1
IMAGE ACQUISITIONEPU2.8.1
CTF CORRECTIONGctf0.53
MODEL FITTINGCoot0.9.6
MODEL FITTINGUCSF ChimeraX1.14
INITIAL EULER ASSIGNMENTcryoSPARC3.3
FINAL EULER ASSIGNMENTcryoSPARC3.3
CLASSIFICATIONcryoSPARC3.1
RECONSTRUCTIONcryoSPARC3.3
MODEL REFINEMENTPHENIX1.19.2_4158
MODEL REFINEMENTLIBGccp4-8.0
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION1372803