ELECTRON MICROSCOPY
Starting Model(s)
| Initial Refinement Model(s) | |||
|---|---|---|---|
| Type | Source | Accession Code | Details |
| experimental model | PDB | 8PHZ | |
| Sample |
|---|
| Helical scaffold assembly of CHIKV nsP3 mediated by its Unique alphavirus domain. |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | HELICAL ARRAY |
| Vitrification Instrument | |
| Cryogen Name | ETHANE-PROPANE |
| Sample Vitrification Details | |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | HELICAL |
| Number of Particles | 807973 |
| Reported Resolution (Å) | 2.52 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | The assembly was calculated from the helical reconstruction of nsP3 from PDB 8PHZ subunit A. This was refined on a local refinement map at 2.35 A reso ... |
| Refinement Type | |
| Symmetry Type | HELICAL |
| Axial Symmetry | C1 |
| Axial Rise | 2.782 |
| Angular Rotation | -164.175 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 (8PHZ) | ||||
| Refinement Space | |||||
| Refinement Protocol | AB INITIO MODEL | ||||
| Refinement Target | |||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | |||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K3 BIOQUANTUM (6k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 18.1 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | FEI TITAN KRIOS |
| Minimum Defocus (nm) | 800 |
| Maximum Defocus (nm) | 2500 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | |
| Nominal Magnification | |
| Calibrated Magnification | |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| CTF CORRECTION | cryoSPARC | |
| RECONSTRUCTION | cryoSPARC | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | ||||