☰ Navigation Tabs
Structure of human gamma-secretase PSEN1 APH-1B isoform reconstituted into lipid nanodisc in complex with Ab46
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 6IYC in silico model Modeller
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 15.987 f_angle_d 0.819 f_chiral_restr 0.051 f_plane_restr 0.007 f_bond_d 0.004
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument GATAN CRYOPLUNGE 3 Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 53612 Reported Resolution (Å) 3.4 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C1
Map-Model Fitting and Refinement Id 1 (6IYC) Refinement Space REAL Refinement Protocol FLEXIBLE FIT Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 56
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model JEOL CRYO ARM 300 Minimum Defocus (nm) 1300 Maximum Defocus (nm) 2300 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.55 Imaging Mode BRIGHT FIELD Specimen Holder Model JEOL CRYOSPECPORTER Nominal Magnification 60000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION crYOLO 1.7 IMAGE ACQUISITION SerialEM 3.8.18 CTF CORRECTION CTFFIND 4.1.14 MODEL FITTING Coot 0.9.8 MODEL REFINEMENT PHENIX 1.19.2 INITIAL EULER ASSIGNMENT RELION 3.1 FINAL EULER ASSIGNMENT RELION 3.1 CLASSIFICATION RELION 3.1 RECONSTRUCTION RELION 3.1
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION 2788683