8OLT

Mitochondrial complex I from Mus musculus in the active state bound with piericidin A


ELECTRON MICROSCOPY
Sample
Mitochondrial respiratory complex I
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Detailsblot for 10 to 12 seconds before plunging
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles41670
Reported Resolution (Å)2.84
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsThis is the combined particles from the two branches of data collected on the two different detectors
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (6ZR2)
Refinement SpaceREAL
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)FEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)5046
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)2200
Maximum Defocus (nm)3400
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification47600
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.1
IMAGE ACQUISITIONEPU
CTF CORRECTIONRELION3.1
CTF CORRECTIONCTFFIND4.1.1
MODEL FITTINGUCSF Chimera1.13.1
MODEL FITTINGUCSF ChimeraX1.4
MODEL FITTINGCoot0.9-pre
MODEL FITTINGCoot0.9.2
MODEL REFINEMENTPHENIX1.18.2-3874
INITIAL EULER ASSIGNMENTRELION3.1
FINAL EULER ASSIGNMENTRELION3.1
CLASSIFICATIONRELION3.1
RECONSTRUCTIONRELION3.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION63952This is from an initial of 36,759 and 27,193 particles from the Falcon III and K2 detectors, respectively.