8OJC

HSV-1 DNA polymerase active site in alternative exonuclease state


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_lrange_it19.445
r_lrange_other19.264
r_dihedral_angle_6_deg15.978
r_dihedral_angle_3_deg12.635
r_scangle_it10.479
r_scangle_other10.477
r_mcangle_it9.469
r_mcangle_other9.467
r_dihedral_angle_1_deg6.716
r_scbond_it5.96
RMS Deviations
KeyRefinement Restraint Deviation
r_lrange_it19.445
r_lrange_other19.264
r_dihedral_angle_6_deg15.978
r_dihedral_angle_3_deg12.635
r_scangle_it10.479
r_scangle_other10.477
r_mcangle_it9.469
r_mcangle_other9.467
r_dihedral_angle_1_deg6.716
r_scbond_it5.96
r_scbond_other5.958
r_mcbond_other5.41
r_mcbond_it5.409
r_dihedral_angle_2_deg4.906
r_angle_refined_deg1.323
r_angle_other_deg0.442
r_metal_ion_refined0.265
r_nbd_refined0.199
r_symmetry_nbd_other0.188
r_xyhbond_nbd_refined0.179
r_nbtor_refined0.177
r_symmetry_nbtor_other0.077
r_chiral_restr0.068
r_dihedral_angle_other_2_deg0.067
r_bond_refined_d0.007
r_gen_planes_refined0.007
r_gen_planes_other0.001
r_bond_other_d
Sample
HSV-1 DNA polymerase-processivity factor complex in exonuclease state
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE-PROPANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles48633
Reported Resolution (Å)2.08
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (7LUF)
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)58
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)500
Maximum Defocus (nm)1500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification165000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC3.3
IMAGE ACQUISITIONEPU
CTF CORRECTIONCTFFIND4.1
MODEL FITTINGUCSF ChimeraX
MODEL REFINEMENTCoot
INITIAL EULER ASSIGNMENTcryoSPARC3.3
FINAL EULER ASSIGNMENTcryoSPARC4
RECONSTRUCTIONcryoSPARC4
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONE