8GNK

CryoEM structure of cytosol-facing, substrate-bound ratGAT1


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d7.999
f_angle_d0.506
f_chiral_restr0.039
f_plane_restr0.004
f_bond_d0.003
Sample
Complex of epitope engineered ratGAT1-Fab9d5
Sample Components
ratGAT1
fragment antigen binding 9D5 heavy/light chain
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles872611
Reported Resolution (Å)3.1
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolOTHER
Refinement TargetCorrelation coefficient
Overall B Value165
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)50.09
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)500
Maximum Defocus (nm)4000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification105000
Calibrated Magnification105000
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC3.0
IMAGE ACQUISITIONEPU2.14
CTF CORRECTIONMotionCorr22
MODEL FITTINGCoot0.9
MODEL REFINEMENTPHENIX
CLASSIFICATIONcryoSPARC3
RECONSTRUCTIONcryoSPARC3
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION5838634