8F8T

Cryo-EM structure of the Tropomodulin-capped pointed end of F-actin


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d14.002
f_angle_d0.916
f_chiral_restr0.057
f_plane_restr0.008
f_bond_d0.005
Sample
Tropomodulin-capped pointed end of F-actin
Sample Components
Tropomodulin (Tmod)
Actin filament
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification DetailsBlot force 0 Blot time 2.5 s
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles25004
Reported Resolution (Å)3.26
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement TargetCross-correlation coefficient
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)44.7
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)500
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification81000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONTopaz0.2.4
CTF CORRECTIONcryoSPARC3.3.2
MODEL FITTINGCoot
MODEL REFINEMENTPHENIX
RECONSTRUCTIONcryoSPARC4.0.0
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION1102793Topaz particle picking with training