8D87
Fitted crystal structure of the homotrimer of fusion glycoprotein E1 from SFV into subtomogram averaged CHIKV E1 glycoprotein density
ELECTRON MICROSCOPY
Crystallization
Crystalization Experiments | ||||
---|---|---|---|---|
ID | Method | pH | Temperature | Details |
1 | 4 | PEG 400, NABR, DETERGENT DDAO, HO3+, VAPOR DIFFUSION, HANGING DROP, PH 4, TEMPERATURE 277.0K |
Crystal Properties | |
---|---|
Matthews coefficient | Solvent content |
5.15 | 76.1 |
Diffraction
Radiation Source | |||||
---|---|---|---|---|---|
ID # | Source | Type | Wavelength List | Synchrotron Site | Beamline |
1 | SYNCHROTRON | SLS BEAMLINE X06SA | 1.53596, 1.53646, 1.18080 | SLS | X06SA |
2 | SYNCHROTRON | ESRF BEAMLINE ID29 | ESRF | ID29 | |
3 | SYNCHROTRON | ESRF BEAMLINE ID14-1 | ESRF | ID14-1 |
Data Collection
Sample |
---|
Sub-tomogram averaged map of post-fusion E1 glycoprotein trimer from Chikungunya virus |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | blot for 7-8 seconds |
3D Reconstruction | |
---|---|
Reconstruction Method | SUBTOMOGRAM AVERAGING |
Number of Particles | 590 |
Reported Resolution (Å) | 27.2 |
Resolution Method | FSC 0.5 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C3 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (1RER) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | RIGID BODY FIT | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 70 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 2500 |
Maximum Defocus (nm) | 5000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 53000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
VOLUME SELECTION | PEET | |
IMAGE ACQUISITION | Leginon | |
IMAGE ACQUISITION | SerialEM | |
CTF CORRECTION | CTFPHASEFLIP | |
MODEL FITTING | UCSF Chimera | |
RECONSTRUCTION | PEET | |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION |