8ANA

Cryo-EM structure of the proline-rich antimicrobial peptide drosocin bound to the 50S ribosomal subunit


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_3_deg10.29
r_dihedral_angle_1_deg5.558
r_long_range_B_refined4.835
r_long_range_B_other4.834
r_mcangle_it2.974
r_mcangle_other2.974
r_dihedral_angle_2_deg2.795
r_scangle_other2.384
r_mcbond_it1.589
r_mcbond_other1.589
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_3_deg10.29
r_dihedral_angle_1_deg5.558
r_long_range_B_refined4.835
r_long_range_B_other4.834
r_mcangle_it2.974
r_mcangle_other2.974
r_dihedral_angle_2_deg2.795
r_scangle_other2.384
r_mcbond_it1.589
r_mcbond_other1.589
r_scbond_it1.316
r_scbond_other1.316
r_angle_refined_deg0.928
r_angle_other_deg0.872
r_chiral_restr0.126
r_gen_planes_refined0.005
r_bond_refined_d0.004
r_bond_other_d0.004
r_gen_planes_other0.004
r_dihedral_angle_4_deg
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Cryo-EM structure of the proline-rich antimicrobial peptide drosocin bound to the 50S ribosomal subunit
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE-PROPANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles159749
Reported Resolution (Å)2.1
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON IV (4k x 4k)
Electron Dose (electrons/Å**2)40
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)400
Maximum Defocus (nm)900
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
CTF CORRECTIONCTFFIND4.1.14
INITIAL EULER ASSIGNMENTRELION4.0
FINAL EULER ASSIGNMENTRELION4.0
CLASSIFICATIONRELION4.0
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION