Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d12.903
f_angle_d0.656
f_chiral_restr0.044
f_bond_d0.008
f_plane_restr0.004
Sample
homoheptameric complex of MscS coordinated with lipids and detergents DDM and LMNG
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details7 sec blotting, blot force +25
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles232197
Reported Resolution (Å)2.3
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC7
Map-Model Fitting and Refinement
Id1 (5AJI)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement TargetWEIGHTED MAP SUM AT ATOM CENTERS
Overall B Value52
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)78
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification75000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.1
IMAGE ACQUISITIONEPU
CTF CORRECTIONCTFFIND4
MODEL FITTINGCoot0.9.2
INITIAL EULER ASSIGNMENTRELION3.1
FINAL EULER ASSIGNMENTRELION3.1
CLASSIFICATIONRELION3.1
RECONSTRUCTIONRELION3.1
MODEL REFINEMENTPHENIX1.19
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION3544930