Cryo-EM structure of aIF1A:aIF5B:Met-tRNAiMet complex from a Pyrococcus abyssi 30S initiation complex
ELECTRON MICROSCOPY
Refinement
| RMS Deviations | |
|---|---|
| Key | Refinement Restraint Deviation |
| f_dihedral_angle_d | 12.249 |
| f_angle_d | 0.474 |
| f_chiral_restr | 0.04 |
| f_plane_restr | 0.004 |
| f_bond_d | 0.002 |
| Sample |
|---|
| tRNA-aIF5B-aIF1A moiety of a Pyrococcus abyssi translation initiation complex with 30S ribosomal subunit,tRNA, mRNA and initiation factors 1A and 5B. |
| Sample Components |
| tRNA-Met |
| Translation initiation factor 1A and Probable translation initiation factor IF-2 |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 37000 |
| Reported Resolution (Å) | 3.6 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | Resolution calculated by the post-processing procedure in Relion. |
| Refinement Type | |
| Symmetry Type | POINT |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 | ||||
| Refinement Space | |||||
| Refinement Protocol | |||||
| Refinement Target | |||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | |||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K3 BIOQUANTUM (6k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 39 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | TFS KRIOS |
| Minimum Defocus (nm) | 800 |
| Maximum Defocus (nm) | 2500 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
| Nominal Magnification | |
| Calibrated Magnification | |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| MODEL REFINEMENT | PHENIX | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | 2000000 | |||