☰ Navigation Tabs
Cytoplasmic dynein (A1) bound to BICDR1
Sample Complex of dynein, dynactin, and BICDR1 bound to microtubules Sample Components Dynein, cytoplasmic 1 Dynactin BICDR1
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details 20 second incubation
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 39644 Reported Resolution (Å) 4.37 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT
Map-Model Fitting and Refinement Id 1 Refinement Space REAL Refinement Protocol FLEXIBLE FIT Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 BIOQUANTUM (6k x 4k) Electron Dose (electrons/Å**2) 53
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 1200 Maximum Defocus (nm) 4000 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification 81000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version IMAGE ACQUISITION EPU MODEL FITTING Coot MODEL REFINEMENT PHENIX INITIAL EULER ASSIGNMENT RELION FINAL EULER ASSIGNMENT RELION RECONSTRUCTION RELION
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION