7Y58

CryoEM structure of QacA (D411N), an antibacterial efflux transporter from Staphylococcus aureus


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d5.412
f_angle_d0.702
f_chiral_restr0.041
f_plane_restr0.005
f_bond_d0.003
Sample
Heterotrimer of QacA (54kDa) in complexed with two single domain camelid antibodies (A4/B7)
Sample Components
QacA (54kDa)
antibodies (A4/B7)
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Detailsblot time of 5 to 6 seconds before plunging
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles218040
Reported Resolution (Å)3.8
Resolution MethodFSC 0.143 CUT-OFF
Other Detailsmaps were derived from non uniform refinement follwed by density modification in phenix which yielded a resolution of 3.6 angstroms
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolAB INITIO MODEL
Refinement Target
Overall B Value201
Fitting Procedure
DetailsReal space refinement
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)51
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1500
Maximum Defocus (nm)4500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification105000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
MODEL REFINEMENTPHENIX1.20rc4_4425:
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION502364