7VPI

Cryo-EM structure of the human ATP13A2 (E1-ATP state)


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg37.515
r_dihedral_angle_3_deg26.874
r_long_range_B_refined20.488
r_long_range_B_other20.488
r_dihedral_angle_4_deg17.985
r_dihedral_angle_1_deg6.411
r_mcangle_it3.755
r_mcangle_other3.755
r_mcbond_it1.96
r_mcbond_other1.96
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg37.515
r_dihedral_angle_3_deg26.874
r_long_range_B_refined20.488
r_long_range_B_other20.488
r_dihedral_angle_4_deg17.985
r_dihedral_angle_1_deg6.411
r_mcangle_it3.755
r_mcangle_other3.755
r_mcbond_it1.96
r_mcbond_other1.96
r_angle_refined_deg1.939
r_scangle_other1.747
r_angle_other_deg1.266
r_scbond_it0.67
r_scbond_other0.669
r_chiral_restr0.105
r_bond_other_d0.023
r_gen_planes_refined0.009
r_bond_refined_d0.008
r_gen_planes_other0.005
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
ATP13A2
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles3114
Reported Resolution (Å)3.6
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement SpaceRECIPROCAL
Refinement ProtocolAB INITIO MODEL
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONCTFFIND
MODEL FITTINGREFMAC
MODEL REFINEMENTREFMAC
INITIAL EULER ASSIGNMENTRELION3.1
FINAL EULER ASSIGNMENTRELION3.1
RECONSTRUCTIONRELION3.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION