☰ Navigation Tabs
I-F3b Cascade-TniQ partial R-loop complex
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 6PIF
Sample I-F3b Cascade-TniQ Full R-loop complex
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 34800 Reported Resolution (Å) 4.03 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT
Map-Model Fitting and Refinement Id 1 (6PIF) Refinement Space Refinement Protocol AB INITIO MODEL Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 BIOQUANTUM (6k x 4k) Electron Dose (electrons/Å**2) 60
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 1000 Maximum Defocus (nm) 2500 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION Topaz IMAGE ACQUISITION SerialEM CTF CORRECTION Warp MODEL FITTING UCSF Chimera MODEL REFINEMENT Coot MODEL REFINEMENT RosettaEM MODEL REFINEMENT PHENIX INITIAL EULER ASSIGNMENT cryoSPARC FINAL EULER ASSIGNMENT RELION
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION